如何正確選型 儀表的選型是儀表應(yīng)用中非常重要的工作,有關(guān)資料表明,儀表在實(shí)際應(yīng)用中有2/3的故障是儀表的錯(cuò)誤選型的安裝而造成的,請(qǐng)?zhí)貏e注意。收集數(shù)據(jù)①被測(cè)流體成分②最大流量、最小流量③最高工作壓力④最高溫度、最低溫度被測(cè)流體必須具備一定的導(dǎo)電性,導(dǎo)電率>5 s/cm。最大流量和最小流量必須符合下表中的數(shù)。內(nèi)徑(mm)1015202532405065Qmin(m3/h)0.08480.19080.33910.52990.86811.35652.11953.5820Qmin(m3/h)3.397.6313.5621.2034.7354.2684.78143.28內(nèi)徑(mm)80100125150200250300350Qmin(m3/h)5.42598.47813.246919.075533.91252.987576.302103.8555Qmin(m3/h)217.04339.12529.88763.021356.482119.53052.084154.22內(nèi)徑(mm)400450500550600700800900Qmin(m3/h)135.648171.6795211.95256.46305.208415.422542.592686.718Qmin(m3/h)5425.966867.18847810258.3812208.2216616.8821703.6827468.82內(nèi)徑(mm)10001100120014001600180020002200Qmin(m3/h)847.801025.8381220.8321660.6882170.3682746.8723991.204103.352Qmin(m3/h)3391241033.5248833.286647.5286814.72109874.88135648164134.08流量計(jì)算公式:Q=V (D/2)2=0.002826VD2 式中:Q-m3/h,V-m/s,D-mm流速范圍:0.3-12m/s(擴(kuò)展范圍0.1-15m/s也有對(duì)應(yīng)可能)●實(shí)際最高工作壓力必須小于流量計(jì)的額定工作壓力。●最高工作溫度和最低工作溫度必須符合流量計(jì)規(guī)定的溫度要求。●確定是否有負(fù)壓情況存在。您可以根據(jù)上表中的流量選擇相應(yīng)的電磁量計(jì),若選擇的電磁流量計(jì)的內(nèi)徑與現(xiàn)在的工藝管道的內(nèi)徑不符,應(yīng)進(jìn)行縮管或擴(kuò)管?!袢艄艿肋M(jìn)行縮管,應(yīng)考慮縮管引起的壓力損失是否會(huì)影響工藝流程?!駨漠a(chǎn)品價(jià)格上考慮,可選擇小口徑的電磁流量計(jì)相對(duì)減少投資。●測(cè)潔凈水時(shí),其經(jīng)濟(jì)流速是1.5-3m/s;測(cè)易結(jié)晶的溶液時(shí),應(yīng)適當(dāng)提高流速,3-4m/s為宜,起到自清掃,防止粘附沉積等作用;測(cè)礦漿等磨耗性流體時(shí),應(yīng)適當(dāng)降低流速,1.0-2m/s為宜,以降低對(duì)內(nèi)襯和電極的磨損。實(shí)際應(yīng)用很少超過7m/s,超過10m/s更為罕見。